Ductless mini split..evaporator leaking. I couldn't find any leaks with soap and electronic detector so put dye in it and voila....
Ductless mini split..evaporator leaking. I couldnt find any leaks with soap and electronic detector so put dye in it and voila....
Wow...oil everywhere. Somebody didn't secure filter drier and rubbed on the bottom. And guess what? There was a pin hole on the bottom of the filter drier and All the refrigerant was blown out. Cheap guys always do like this. #refrigeration #[email protected] #repair #cooler #freezer #calgary #hvacr #maintenance @ Calgary, Alberta
Navien NR-240A heat exchanger leaking
Summer is just around the corner.
Navien NR series Tankless water heater heat exchanger problem
Wow...oil everywhere. Somebody didnt secure filter drier and rubbed on the bottom. And guess what? There was a pin hole on the bottom of the filter drier and All the refrigerant was blown out. Cheap guys always do like this. #refrigeration #[email protected] #repair #cooler #freezer #calgary #hvacr #maintenance @ Calgary, Alberta
What happened? I am not sure but I think someone just might want to check pressure switch without reading diagram. #djmheating #rtu #Refrigeration #aircondition #calgray #hvac #hvacr #repairservice
It is gross. Plugged condensate trap on carrier furnace. Water leaking from inside of furnace and giving an error code
Carrier furnace secondary heat exchanger leaking
Pretty old rooftop unit. Wires damaged
Another heat exchanger problem....its York
Carrier...secondary heat exchanger problem @ Calgary, Alberta
Guess what....somebody applied 208v to 115v unit. #walkin #cooler #freezer #refrigeration #djmheating @ Calgary, Alberta
Snow snow snow....I shoveled my driveway 4 times today. It is the first shovel and after 2-3 hours, there was a pile of snow like that much on the driveway
What a mess!!! I am not a plumber but made a little organized
Reach in cooler suction line I dont know who did like this
Noisy inducer motor. Something happened to heat exchanger #carrierfurnace #djmheating #heatexchanger
Old fridge...r12 leaking #djmheating #refrigeration #evaporator
Wow..walk in freezer lineset rubbing each other and leaking. The system lost 4 lbs of refrigerant in 2 days. What a mess installation DJM Heating and Refrigeration 403-775-2472... #djmheating #freezer #repair #refrigeration #calgary #yyc #restaurant @ Calgary, Alberta
Walk in #freezer hunting. Hmm.. nice ice coat on #txv and distributor. Cleaned inlet screen and adjusted spring force DJM HEATING AND REFRIGERATION 403-775-2472... #djmheating #a/c #service #repair #cooler #calgary #refrigeration #commercial #restaurant
Condenser coil is wearing thick coat. Too hot....A/C tune up and repair or installation DJM Heating and Refrigeration 403-775-2472 [email protected]
Cut and open hermetic scroll compressor and I found a broken piece @ Calgary, Alberta
Compressor is dead. Someone repaired leaks 2 years ago and overcharged. Factory charge is 5 lbs 4 oz and guess what?? 8 lbs 2 oz. lol @ Calgary, Alberta
Wow...It could be your A/C A/C tune up, repair, installation DJM Heating and Refrigeration 403-775-2472
qute ice buildup
Walk in freezer contactor...burnt wires
Carrier 10 year old furnace. Secondary heat exchanger corroded and leaking. Error code #13. If you have around 10 years old Carrier high efficiency furnace and feel something wrong, please let us know. We can find the problem and fix properly. DJM Heating and Refrigeration. [email protected] 403-775-2472
Best service guaranteed
Pretty old pop machine. Vanishing vintage rebuilt these machines and DJM Heating and Refrigeration repaired refrigeration system. Some units have old pancake compressors running.
Walk in cooler - rust and crack on suction filter. Found during the maintenance.
Multiple leaks on evaporator coil. No refrigerant left in the system. Replaced the coil. DJM Heating and Refrigeration 403-775-2472
Broken MUA blower wheel. Upgraded blower with heavy duty frame
Dirty coil causes a lot of problems on your A/C. Clean evaporator and condenser coil before Summer. Contact me for coil cleaning and tune up. DJM HEATING AND REFRIGERATION 403-775-2472
Popular Listings
DeSimone Architect Incorporated
497 Main Street East Hamilton, ON, Canada
+1 905-520-6417
Home improvement, Carpenter, Architectural designer, Engineering service
Big Glass Openings
124 Brock Street L4N 2M2 Barrie, ON, Canada
+1 705-915-1616
Home improvement, Glass service, Home window service, Architectural designer
AAA Door Guys Inc
+1 705-739-6666
Home improvement, Garage door service